Energy Recovery Ventilator (ERV)

The EXINDA 100 CFM ERV is engineered to improve indoor air quality and reduce energy consumption by recovering heat and humidity from exhaust air before it leaves the building. With auto-balancing airflow, quiet ECM motors, and flexible mounting options, it delivers stable, efficient ventilation for medium-to-large homes and light commercial spaces.

Designed to operate from –18°F to 109°F, this ERV maintains balanced fresh-air delivery even under changing pressure, duct resistance, or filter loading.

EXINDA 100 CFM Energy Recovery Ventilator (ERV)

The EXINDA ICMBCNF1AYE Energy Recovery Ventilator provides continuous, balanced ventilation while recovering heat and moisture from outgoing air to precondition incoming fresh air. This process reduces heating and cooling loads, improving overall building efficiency and comfort.

Featuring constant airflow control and auto-balancing technology, the ERV automatically adjusts fan speed to maintain stable ventilation regardless of duct resistance, filter conditions, or pressure variations.
Equipped with ECM brushless motors, washable filters, and a cross-flow ERV core, it ensures long-term reliability and easy maintenance.

Its compact design and flexible mounting options — horizontal or wall-mounted — allow seamless integration into a variety of residential and light commercial installations.

UL 1812 (safety) and CSA 439 (performance) certifications ensure compliance with North American standards.

01 — Heat & Humidity Recovery

Transfers heat and moisture from exhaust air to incoming fresh air, improving comfort and reducing HVAC load.

02 — Constant Airflow Technology

Maintains balanced supply and exhaust airflow automatically, even as duct conditions change.

03 — Auto-Balancing System

Fast installation — reduces setup time by up to 20 minutes per unit thanks to self-adjusting airflow control.

04 — ECM Brushless Motors

High-efficiency, low-noise motors ensure stable and energy-saving performance.

05 — Quiet Operation

Sound levels as low as 24–30 dB(A) depending on speed settings (HH/H/L).

06 — Three Airflow Speeds

Adjustable 53 / 70 / 90 CFM airflow for medium-to-large homes or small commercial spaces.

07 — Flexible Mounting Options

Suitable for horizontal or wall-mounted installations.

08 — Easy Maintenance

Front access door for quick filter cleaning or replacement; includes two washable MERV 8 filters.

09 — Certified Performance

UL 1812 (safety) and CSA 439 (performance) approved.

10 — Wide Operating Range

Works reliably from –18°F to 109°F outdoor temperatures.

Technical Performance

Electrical:

Power Supply: 120V / 60Hz / 1Ph
Power Supply Connections: L, N, Ground
Maximum Input Power: 180 W
MCA: 1.4 A
MOP: 15 A

Airflow & Pressure:

Selectable Airflow Speeds (CFM): 90 / 70 /5 3
External Static Pressure (in. w.g): 0.4 / 0.2 / 0.1

Sound Levels:

Sound Pressure (dB(A)): 30 / 28 / 24 (HH / H / L)

Operating Conditions:

Outdoor Temperature Range: –18°F to 109°F

Filtration:

Indoor Air Filtration: MERV 8 / Washable / x2
ERV Core: Cross-flow, Non-washable

Motor:

● ECM brushless motor
● Digitally controlled, direct drive
● 3 available fan speeds

Dimensions & Weight:

Unit Size (H × W × D): 9 1/12 × 20 1/16 × 20 1/14 in
Net Weight: 36 lb
Gross Weight: 205 lb (from packaging section)

Ventilation Performance:

Heating Mode (32°F / 0°C):
SRE: 77.4%
Adjusted SRE: 80.7%
Cooling Mode (95°F / 35°C):
Total Efficiency: 63.3%
Adjusted Total Recovery: 65.6%

Defrost:

Type: Exhaust-air defrost

Energy Recovery Ventilator (ERV)